Isotherm Internationale
Isotherm Internationale
New Bowenpally, Hyderabad, Telangana
SEND SMS
SEND EMAIL

Electrical Heat Tracers

Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels. Trace heating takes the form of electrical heating elements to run in physical contact along the length of a pipe. The pipe is usually covered with thermal insulation to retain heat losses from the pipe. The Heat generated by the element then maintains the temperature of the pipe. Trace heating may be used to protect pipes from freezing, to maintain a constant flow temperature in hot water systems, or to maintain process temperatures for piping that must transport substances that solidify at ambient temperatures. Electric trace heating cables are an alternative to steam trace heating where steam is unavailable or unwanted.

The most common pipe trace heating applications include:
  • Freeze protection
  • Temperature maintenance
  • Snow Melting on Driveways

Other uses of trace heating cables include:
  • Ramp and stair snow/ice protection
  • Gulley and roof snow/ice protection
  • Underfloor heating
  • Door/frame interface ice protection
  • Window de-misting
  • Anti-condensation
  • Pond freeze protection
  • Soil warming
  • Preventing cavitation
  • Reducing Condensation on Windows

Mineral Insulated Heat Tracer

Mineral Insulated Heat Tracer
  • Mineral Insulated Heat Tracer
  • Mineral Insulated Heat Tracer
  • Mineral Insulated Heat Tracer
Get Best Quote
Approx. Price: Rs 1,000 / MeterGet Latest Price

Product Details:

Minimum Order Quantity500 Meter
BrandIsotherm
Voltage230 V
Temperature1000 Deg C (1832 Deg F)
Phase3 phase
Length6 - 12 m

Mineral Insulated Heat Tracer are made with an individual electrical resistance, further on with high-temperature resistance and used in universal applications. Heating cables are suitable for heating applications up to a maximum sheath temperature of 600'C (stainless steel sheath) or up to 1000'C (Nickel alloy sheath material). The environment temperatures must be considered.

Features:
  • Long circuit lengths available
  • SS and Nickel Alloy sheaths available for flexibility.
  • Used in applications such as process temperature maintenance, vessel heating, etc.
  • Custom configurations available
Request
Callback
Yes! I am Interested

Self Regulating Heat Tracer

Self Regulating Heat Tracer
  • Self Regulating Heat Tracer
  • Self Regulating Heat Tracer
Get Best Quote
Approx. Price: Rs 600 / MeterGet Latest Price

Product Details:

Minimum Order Quantity500 Meter
Usage/ApplicationIndustrial Ovens
BrandIsotherm
Voltage230 V
Temperature155 Deg C (311 Deg F)
Output60 W/m

Self Regulating Heat Tracer that automatically adjust their power output to compensate for temperature changes. ISOTHERM self-regulating heating cables consist of two parallel conductors embedded in a heating core made of conductive polymer. The core is radiation-crosslinked to ensure long-term reliability. Heat is generated as electric current passes through the conductive polymer core between the cable’s conductors. As the ambient temperature drops, the number of electrical paths through the core increases and more heat is produced. Conversely, as the temperature rises, the core has fewer electrical paths and less heat is produced. ISOTHERM™ Self- Regulating Heating Cable has passed IEC EX, ATEX, and CE for the European market, and EAC for the Russian market.

Features:
  • Long circuit lengths available
  • Thermoplastic and Fluoropolymer sheaths available for flexibility
  • Used in applications such as freeze protection of long pipework, process temperature maintenance, vessel heating, etc.
  • Cut-to-length and terminated in the field.
Request
Callback
Yes! I am Interested

Series Resistance Heat Tracer

Series Resistance Heat Tracer
  • Series Resistance Heat Tracer
  • Series Resistance Heat Tracer
Get Best Quote
Approx. Price: Rs 250 / MeterGet Latest Price

Product Details:

Minimum Order Quantity500 Meter
BrandIsotherm
Voltage1000 V
Phase3 phase
Temperature280 Deg C (536 Deg F)
Output60 W/m

Isotherm offers series resistance (longline) heating cable for many applications. Series Resistance Heating Cable is designed into particular lengths and load configurations, so they are not as versatile as parallel cables. However, Series Resistance Heating Cable can span moderate distances and provides great overall heating. Isotherm™ is also able to offer custom configurations for those that need more precise specifications on their products. ISOTHERM™ Series Resistance Heating Cable has passed IEC EX, ATEX, and CE for the European market, and EAC for the Russian markets.

Features:
  • Long circuit lengths available
  • Silicone and Fluoropolymer sheaths available for flexibility
  • Used in applications such as freeze protection of long pipework, process temperature maintenance, vessel heating, etc.
  • Custom configurations available.
Request
Callback
Yes! I am Interested

Parallel Constant Watt Heat Tracer

Parallel Constant Watt Heat Tracer
  • Parallel Constant Watt Heat Tracer
Get Best Quote
Approx. Price: Rs 400 / MeterGet Latest Price

Product Details:

Minimum Order Quantity50 Meter
Usage/ApplicationChemicals, furnaces Oils, storage tanks of Boilers, furnaces DG Set etc
BrandIsotherm
Insulated MaterialPTFE
Temperature280 Deg C

ISOTHERM™ Parallel Circuit Heating Cable is a twin-conductor constant wattage heating cable. It is designed for pipe, storage tank and other equipment heat-tracing in industrial applications. It is widely used in carbon steel pipes, stainless steel pipes, painted and unpainted metal pipes. The regular models in markets are 10w/m to 40w/m. You can also customize any wattage heating cable you want. ISOTHERM™ Parallel Circuit Heating Cable heats up through the heating wires in parallel. It is the parallel construction that allows it to be cut-to-length and terminated in the field. ISOTHERM™ Parallel Circuit Heating Cable has passed IEC EX, ATEX, and CE for the European market, and EAC for the Russian market.

Features:
  • Long circuit lengths available
  • Silicone and Fluoropolymer sheaths available for flexibility
  • Used in applications such as freeze protection of long pipework, process temperature maintenance, vessel heating, etc.
  • Cut-to-length and terminated in the field.
Request
Callback
Yes! I am Interested
X

Explore more products



Reach Us
Rohith Rao (Marketing Manager)
S-2, B. R. Apartments, Chinna Thokatta, New Bowenpally Road
Hyderabad- 500009, Telangana, India



Call Us

Share Us

F GT L


Send E-mailSend SMS